AcrySof phakic angle-supported intraocular lens for the correction of moderate-to-high myopia: one-year results of a multicenter European study.

Tipo: Artículo
Autores: Kohnen T, Knorz MC, Cochener B, Gerl RH, Arné JL, Colin J, Alió JL, Bellucci R, Marinho A.
Títuto Revista: Ophthalmology
Referencia:
Centro: 14 - IOA - UMH
Ophthalmology. 2009 Jul;116(7):1314-21, 1321.e1-3. Epub 2009 May 30.

AcrySof phakic angle-supported intraocular lens for the correction of moderate-to-high myopia: one-year results of a multicenter European study.

Source

Johann Wolfgang Goethe-University, Department of Ophthalmology, Frankfurt/Main, Germany. kohnen@em.unifrankfurt.de

Abstract

PURPOSE: To investigate the safety and effectiveness of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX) for correction of moderate-to-high myopia in adults.

DESIGN: One-year interim analysis of a phase 3, nonrandomized, open-label, prospective, multicenter European clinical study.

PARTICIPANTS: A total of 190 subjects (190 eyes) with moderate-to-high myopia. The preoperative mean manifest refraction spherical equivalent (MRSE) was -10.38 diopters (D) +/-2.43 standard deviation (SD).

METHODS: Unilateral implantation of the AcrySof phakic angle-supported IOL.

MAIN OUTCOME MEASURES: Best spectacle-corrected visual acuity (BSCVA), uncorrected distance visual acuity (UCVA), predictability and stability of MRSE, adverse events, and endothelial cell density.

RESULTS:  Of 190 subjects enrolled, 161 completed the 1-year postoperative visit. No subjects lost > or =2 lines BSCVA. A UCVA of 20/20 or better was achieved by 57.8%; 99.4% had 20/40 or better. A BSCVA of 20/32 or better was achieved by 100% of subjects; 85.7% had 20/20 or better. The mean MRSE was -0.23 D (+/-0.50 D: -2.50 to 0.75 D). Residual refractive error was within +/-1.0 D from the target for 95.7% of subjects and within +/-0.5 D for 72.7% of subjects. The overall mean percentage change in central endothelial cell density 1 year after surgery was -4.77+/-8.04% (n = 139). No pupil ovalization, pupillary block, or retinal detachment events were observed.

CONCLUSIONS:  The AcrySof phakic angle-supported IOL yielded excellent refractive correction and predictability with acceptable safety in subjects with moderate-to-high myopia. These 1-year interim analysis findings demonstrate preliminary support for the safety and efficacy of this IOL.

PMID: 19481808 [PubMed - indexed for MEDLINE]